Vanagon Syncro AWD L4-2109cc 2.1L (1987)
Syncro
Step 3. Continued
^
connect fuel pressure gauge VW 1318 to vacant fitting on pressure regulator with Digifant adapter VW 1318/17 (arrow)
Note:
Valve on pressure gauge must be in CLOSED position (as shown)
Vanagon
Syncro
^
connect US G16 adapter kit (modified with shut-off valve) to open end of fuel feed hose using Digifant adapter-nipple (arrow)
Note:
Valve on adapter kit must be in CLOSED position (as shown)
WARNING
Safety glasses MUST be worn while performing Step 3.
WARNING
Hand tighten only.
Step 3. Continued
^
reinstall intake air boot (not removed on Syncro)
^
connect VW 1367 engine tester with VW 1473 voltage splitter to engine. DO NOT connect exhaust analyzer at this time as it may clog very
quickly during cleaning procedure