volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Catalytic Converter > < Pulsair Maintenance|Page 1350
Page 1
background image

Pulsed Secondary Air Injection: Service and Repair
Installing Shut-Off Valve

Fig. 59 PULSAIR SHUT-OFF VALVE

Installing shut-off valve on previous models:
The shut-off valve can be installed on vehicles with carburetor engines only. 
Cut the hose from the air cleaner to the PULS-AIR system and shorten it about 30mm (1.2in). Do this some distance away from the bend on the hose. 
Push the valve into position.

NOTE:
The arrow must point towards the engine. Fig. 59.

Install the control hose on the valve. The length of the hose should be approx. 550mm (22in).

Cars with manual transmission:
Remove the plug from the intake manifold and screw the nipple into position. Connect the control hose and secure it with tie straps.

Cars with automatic transmission:
Cut existing hose to the intake manifold. Install a T-type connector on the hose. Connect the control hose and secure it with tie straps.