volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Function Check|Page 2929 > < Function Check
Page 2
background image

-Check the HO2S reference voltage

If the reading is constant over 1.0 V:

-Check the HO2S reference voltage EJ2.

EJ2

Checking The Heated Oxygen Sensor (HO2S) Reference Voltage

-Ignition on.

-Disconnect the HO2S 1-pole connector.

Connect a voltmeter between the 1-pole connector (by the control module) and GND.

The voltmeter should read approx. 0.5 V.

If this value is OK:

-Check the MAF sensor GND point EJ8.

If the reading is approx. 0 V:

-Connect the test box.

If the reading is over 1 volt:

-Check the wiring between MFI #24 and the HO2S for short circuits.

When the fault has been remedied:

-Check the signal from the HO2S in accordance with EJ1.

EJ3

Connecting The Test Box

Connect the test box to MFI LH 2.4/LH 3.1 and check the GND points in accordance with P1-P2.

-Continue with Checking the signal wiring EJ4.

EJ4

Checking Signal Wiring

Function Check|Page 2929 > < Function Check