volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Power Stage #1 No Ignition Signal|Page 3950 > < Power Stage #1 No Ignition Signal|Page 3948
Page 1
background image

Ignition Power Stage: Testing and Inspection
Power Stage #2 No Power Stage GND

UG. POWER STAGE #2

Power stage #2 No power stage GND

Fault Message Conditions:

A fault message is recorded if voltage exceeds 

1.2 V.

Fault causes:

Break between power stage terminal 2 and the GND point on the intake manifold.

Poor GND point connection.

Fault symptoms:

The engine will not start.

If the fault is intermittent the engine will stop or run roughly.

UG1

Volvo ST, Test Box

-Disconnect the ST in accordance with QA2.

-Continue with Checking the GND point UG2.

UG2

Checking The GND Point

-Ignition off.

Connect an ohmmeter between power stage terminal 2 and GND.

The ohmmeter should read approx. 

0 OHMS.

Power Stage #1 No Ignition Signal|Page 3950 > < Power Stage #1 No Ignition Signal|Page 3948