volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Function Check|Page 2343 > < Function Check|Page 2341
Page 3
background image

-Ignition off

Connect an ohmmeter between #24 and #5.

The ohmmeter should read infinite resistance.

If this reading is OK:

-Check the resistance in the wiring EJ5.

If the reading is 0 OHMS.

-Check the wiring to control module #24 for grounding.

EJ5

Checking The Resistance In The Wiring

Connect an ohmmeter between #24 and the 1-pole connector at the firewall (by the control module).

The ohmmeter should read 0 OHMS.

If this value is OK:

-Try using a new control module.

If resistance is infinite:

-Check the wiring to control module #24 for breaks.

EJ6

Checking The Heated Oxygen Sensor (HO2S) Preheater

-Engine running.

Connect a voltmeter between terminal 1 and GND in the 2-pole connector.

Function Check|Page 2343 > < Function Check|Page 2341