volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

TP Switch Signal Faulty at Idle|Page 2511 > < TP Switch Signal Faulty at Idle
Page 2
background image

Entering Control Function #2

If code 3-3-2 is received:

Intermittent fault.

-Check the wiring between terminal 2 in the TP switch connector and MFI #2 as well as terminal 2 in the connector and DI #7 for intermittent
grounding.

-Clean the TP switch connector and treat it for corrosion.

If code 3-3-2 is not received:

-Checking the TP switch EH3.

EH3

Checking The Throttle Position (TP) Switch

-Ignition off.

-Disconnect the TP switch.

Connect an ohmmeter between terminals 18 and 2 on the TP switch.

The ohmmeter should read approx. 0 OHMS.

-Open the throttle a little.

The ohmmeter should read infinite resistance.

If both readings are OK:

-Check the wiring between terminal 2 in the TP switch connector and MFI #2, as well as terminal 2 in the connector and DI #7, for grounding.

-Clean the TP switch connector and treat it for corrosion.

If either or both of the readings are incorrect:

-Try using a new TP switch.

TP Switch Signal Faulty at Idle|Page 2511 > < TP Switch Signal Faulty at Idle