volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Idle Speed > < CO% Adjustment Using Test Diode|Page 1613
Page 3
background image

-

Turn off engine.

Fig. 370 REMOVE CO ADJUSTMENT SEAL

-

Drill two 2 mm (0.08 in.) holes in plug. 

-

Withdraw plug with circlip pliers.

-

Start engine.

-

Adjust CO content so that Mono-tester pointer moves between 2O°-7O°.

Fig. 371 CO ADJUSTMENT

Counterclockwise reduces CO 
Clockwise increases CO
Adjustment range = 15 turns.

-

Seal CO adjustment screw
Always use a new plug. 

-

Push plug into position. 

-

Disconnect test instruments.

Idle Speed > < CO% Adjustment Using Test Diode|Page 1613