740 L4-2.3L SOHC VIN 88 B230F (1985)
1. Install new vacuum motor and reinstall panel to distribution housing (four bolts).
2. Install distribution housing.
3. Connect vacuum lines:
- red to upper shutter for panel vents
- light brown to lower shutter for panel vents
- yellow and blue to floor/defroster shutter (yellow on the innermost).
For more information refer to the vacuum chart. See: Diagrams/Vacuum and Vapor Hose Diagrams
4. Connect distributor to rear floor and install air duct screws.