background image

Fig. 370 REMOVE CO ADJUSTMENT SEAL

-

Drill two 2 mm (0.08 in.) holes in plug. 

-

Withdraw plug with circlip pliers.

-

Start engine.

-

Adjust CO content. CO screw should be turned until test diode starts to flash.

Fig. 371 CO ADJUSTMENT

Counterclockwise reduces CO 
Clockwise increases CO
Adjustment range = 15 turns.

-

Seal CO adjustment screw
Always use a new plug. 

-

Push plug into position. 

-