760 L4-2320cc 2.3L SOHC Turbo B23FT (1984)
Control Assembly: Testing and Inspection
Programmer Function
Programmer Function (Auto)
The diagram indicates the programmers reaction to incoming resistance signals. If resistance is too low, the ACCU programmer will try to achieve max
cold. If resistance is too high, it will try to achieve max heat.
NOTE:
The programmers are factory adjusted and should not be tampered with.