5. Remove control module and mounting bracket.
6. Disconnect original blower motor and electrical connections
Remove blower motor gasket
7. Cut plastic tube flush with blower housing. Use hacksaw blade. File cut surface level to ensure best possible seal.
8. Install adapter ring. Prior to installation run bead of sealant as per (A) in illustration and plastic foam seal as per (B). Seal only mating face with
blower housing.