760 L4-2320cc 2.3L SOHC Turbo B23FT (1984)
Ambient Temperature Sensor / Switch HVAC: Testing and Inspection
Ambient Temperature Sensor, A/C
NOTE: Sensor resistance drops with increasing temperature.
Check Sensor
-
Use ohmmeter. Carry out measurement at room temperature approx. 2O-23 °C (68-73 °F). Ignition should be switched OFF.
-
Resistance: 30 - 40 Ohms.
-
If resistance is much higher: 65 - 100 Ohms, replace sensor.