volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Blower Housing, Modification For New Spare Motor|Page 2560 > < A/C - Condenser/Pressure Pipe Connections Changed|Page 2555
Page 1
background image

Housing Assembly HVAC: Service and Repair
Blower Housing, Modification For New Spare Motor

CAUTION:  Radio with microprocessor. To prevent damage to the radio microprocessor, the radio must be switched off before disconnecting the
battery ground lead.

NOTE:  When installing a new blower motor on earlier cars with all climate units, the blower housing must be modified to enable the new blower motor
to be used.

Required Material:

Blower motor kit, Part Number 3537854-6, quantity 1.
Soundproofing panel, type 1 Part Number 3527931-4, quantity 1.

Modification:

1. Disconnect battery ground lead.

2. Remove soundproofing panel on passenger side.
3. Remove side panel on passenger side.

4. Disconnect control module connector.

Blower Housing, Modification For New Spare Motor|Page 2560 > < A/C - Condenser/Pressure Pipe Connections Changed|Page 2555