Fuse Holder - Deformed

SECTION

GROUP

NO.

37

104

DATE FEBRUARY 1986

RE:

DEFORMED FUSE HOLDER- 760 WITH ACC
THIS BULLETIN APPLIES TO THE U.S. AND CANADA.

If the central electric fuse holder for the blower motor circuit (30 Amp) deforms, you must check current draw through that circuit. If the current draw is
too high, locate and correct the cause (e.g. blower motor). Blower motor fuse numbers are:
# 16 for 1985 M/Y # 14 for 1983-84 M/Y

Perform the following steps to avoid replacing the complete fuse box assembly.

REQUIRED PARTS:

Description              Part No.          Quantity

In-line fuse holder

1323312-7

1

30 Amp fuse

966331-1

1

14 gauge wire (black)

-------

10-1/2 in. (265 mm)

Female electrical connectors

949201-8

2

Work Sequence:

-

Disconnect battery ground cable

-

Remove glove box

-

Disconnect black (SB) wire from terminal 2 of fan relay and connect it to in-line fuse holder, Part
No. 1323312-7.

-

Crimp female connectors to 10-1/2 in. (265 mm) wire. Connect one end to in-line holder and other
end to terminal 2 of fan relay.

-

Mount fuse holder on lower mounting screen of resistor block (see illus.) and install 30 Amp. fuse,
Part No. 966331-1.

-

Remove ashtray

-

Remove graphic equalizer

-

Remove central electric unit

1985 M/Y Vehicles