760 V6-2849cc 2.8L SOHC B28A (Can) (1984)
25. Place sealant in groove in lower blower housing. Sealant should fill groove completely to ensure perfect seal when blower housing is in place. Run
sealant as indicated by arrows in illustration.
26. Install lower blower housing. Connect electrical leads to blower motor and blower resistors. Adjust wiring.
27. Reinstall:
-
control module bracket
-
control module.
28. Reconnect connector.
29. Reinstall:
-
control module cover
-
battery ground lead.
30. Check blower operation.