Remove all sockets.

Remove rheostat.   See: Service and Repair

Carefully pry off connector holders with a screwdriver.

Remove all screws and nuts retaining circuit card.

Note:  All instruments come free at the same time.

Remove circuit card.

Fit new unit.

Reassemble in reverse order. Tighten all screws well.

Test.

Yazaki circuit card, replacement ..................................................................................................................................................................................  S13
760/960 1988-1994
 

Check that there is no corrosion between screws and circuit card, as per S11.

Remove circuit card holders in upper connector.

Remove all bulb sockets.

Remove rheostat.   See: Service and Repair

Carefully pry off connector holders with a screwdriver.

Remove all screws retaining circuit card.

Note:  All instruments come free at the same time.

Remove circuit card.

Fit new unit.

Reassemble in reverse order. Tighten all screws well.

Test.

Yazaki circuit card, replacement ..................................................................................................................................................................................  S14
940/960 1995-
 

Check that there is no corrosion between screws and circuit card, as per S11.

Remove backplate from housing by removing screws round the edge as shown.

Remove all bulb holders.

Remove rheostat.   See: Service and Repair