volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Antitheft Alarm - Fault Tracing (Watchdog 2)|Page 4144 > < Antitheft Alarm - Fault Tracing (Watchdog 2)|Page 4142
Page 3
background image

T2

+12V (30-supply)

T3

Alarm relay

T4

-

T5

+12V (15-supply)

T6

Vibration sensor

T7

Magnetic switches

T8

Door switch

T9

Lock plate (BL)

T10

Lock plate (GR)

T11

Lock plate (R)

T12

Lock plate, ground (SB)

Fault Tracing 1 & 2 Information

FAULT TRACING 1 NOT POSSIBLE TO ARM/TURN OFF ALARM

CHECK that:
-

there isn't a loudspeaker or another strong magnetic source closer than 200 mm (8 in.) from the lock plate

-

alarm supply voltage is 10-14V. Measure between T2 and T12 as shown.

*The operation has to be done two times to be sure the signal to T10 will switch the alarm on/off switch.

Antitheft Alarm - Fault Tracing (Watchdog 2)|Page 4144 > < Antitheft Alarm - Fault Tracing (Watchdog 2)|Page 4142