volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Courtesy Lamp|Testing and Inspection|Page 20813 > < Courtesy Lamp|Testing and Inspection|Page 20811
Page 3
background image

Close doors and trunk.
Bridge relay base terminals LA and T.
Interior lighting should come on if the trunk or any door is opened.

If lighting comes on:
Check interior lighting ground lead as per C21.

 

If interior lighting does not come on:
Check interior lighting switches in central locking units as per K5.

K5: Checking Interior Lighting Switches In Central Locking Units

Switch off Ignition.
Reinstall central locking relay 2/7.
Remove all door panels.
Open central locking unit connectors.

Front door units.
Connect an ohmmeter between terminals 6 and 14 in central locking unit 14-pin connector.
Ohmmeter should Indicate 0 Ohm with door open. 
Ohmmeter should Indicate infinite resistance with door closed.

Rear door units.
Connect an ohmmeter between terminals 2 and 5 in central locking unit 8-pin connector.
Ohmmeter should Indicate 0 Ohm with door open. Ohmmeter should show Infinite resistance with closed door.

If reading is correct:
Check ground lead to interior lighting switch in central locking unit as per K6.

Courtesy Lamp|Testing and Inspection|Page 20813 > < Courtesy Lamp|Testing and Inspection|Page 20811