volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Courtesy Lamp|Testing and Inspection|Page 20508 > < Courtesy Lamp|Testing and Inspection|Page 20506
Page 5
background image

K7: Delayed Interior lighting Does Not Operate

Switch off Ignition.
Remove central locking relay 2/7.
Connect a voltmeter across relay base terminals 15 and 31.
Voltmeter should indicate 0 V.

If reading is correct:
Check the Interior lighting ground connection as per C21.

If reading Is Incorrect:
Short circuit to supply in lead between fuse holder terminal 11/3:2 (fuse 3) and relay base terminal 15.
Correct fault or replace lead between terminal 11/3:2 and relay base terminal 15. Reinstall central locking relay 2/7.

K8: Delayed Interior Lighting Does Not Switch Off

Switch off Ignition.
Remove central locking relay 2/7.
Switch on ignition.
Connect a voltmeter across relay base terminals 15 and 31.
Voltmeter should indicate battery voltage.

If reading Is correct:
Check interior lighting ground lead as per C21
If reading Is Incorrect:
Check voltage supply (15) to fuse 3 in fusebox as per K9.

K9: Checking Supply (15) To Fuse 3 In Fusebox

Switch off Ignition.
Remove fuse 3. Replace fuse 3 If faulty.

Courtesy Lamp|Testing and Inspection|Page 20508 > < Courtesy Lamp|Testing and Inspection|Page 20506