Air Door Cable: Service and Repair
Air Duct Cable

Adjustment of control wires:

Before adjusting control wires, try adjusting lower attachment of cable to climate control unit.
1. Remove soundproofing.

-

Remove left- or right-hand soundproofing (depending on cable to be adjusted).

2. Disconnect cable sleeve concerned from its clip.

-

Left-hand temperature damper cable (1). Turn left-hand temperature damper to 0. Push lever as far down as it will go and then push cable
sleeve into clip.

-

Right-hand temperature damper cable (2). Turn right-hand temperature damper to 0. Push lever as far down as it will go and then push cable
sleeve into clip.

-

Ventilation and floor/defroster damper cables (3). Set control to DEFROST (12 0'clock position). Push ventilation and floor/defroster levers
to end position and then push sleeves into respective clips.

If this adjustment does not work, the upper cable fittings must be adjusted, go to step 3.