Canister Purge Control Valve: Testing and Inspection

Checking EVAP Valve
^

Remove following to gain access to EVAP valve:
-

Valve from bracket.

-

Soundproofing from valve.

^

Remove / Disconnect:
-

Tool P/N 9995545 and pressure regulator P/N 9995544 from fresh air hose.

-

Hoses from EVAP valve.

-

Connector.

^

Connect hose from vacuum pump P/N 9995843 to connection point under connector.

^

Pump up vacuum.

^

Vacuum gauge should indicate steady value.

If vacuum falls:
-

Replace EVAP valve.

^

Reinstall valve, hoses, soundproofing and connector on completion of check. 

^

Use clamp P/N 9814215 and new hose clip, P/N 978165-9, when installing.