850 Turbo L5-2.3L Turbo VIN 57 B5234FT (1996)
Canister Purge Control Valve: Testing and Inspection
Checking EVAP Valve
^
Remove following to gain access to EVAP valve:
-
Valve from bracket.
-
Soundproofing from valve.
^
Remove / Disconnect:
-
Tool P/N 9995545 and pressure regulator P/N 9995544 from fresh air hose.
-
Hoses from EVAP valve.
-
Connector.
^
Connect hose from vacuum pump P/N 9995843 to connection point under connector.
^
Pump up vacuum.
^
Vacuum gauge should indicate steady value.
If vacuum falls:
-
Replace EVAP valve.
^
Reinstall valve, hoses, soundproofing and connector on completion of check.
^
Use clamp P/N 9814215 and new hose clip, P/N 978165-9, when installing.