volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

A/C - Unpleasent Odor On Startup|Page 397 > < A/C - Unpleasent Odor On Startup|Page 395
Page 22
background image

E8
Connection of 10-pin contact
-

Separate the halves of the 10-pin connector at the centre console and install the 10-pin connectors from the new cables.

E9
Fastening cables
-

Attach the cable harness to the defroster duct above the glove compartment using a cable tie.

Function verification and information

E10
Check airing cycle is working
-

Connect battery lead and start car.

-

Turn on A/C system to start compressor.

The A/C system starts if the temperature exceeds approx. 7°C (45°F).
-

Make up a cable (about 2 meters (6 ft.) in length) to connect battery positive terminal to control module connector. Connect to green cable, connector
terminal 6, for at least 30 seconds while compressor is operating.

-

Turn off engine.

A/C - Unpleasent Odor On Startup|Page 397 > < A/C - Unpleasent Odor On Startup|Page 395