volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Temperature Sensor (Gauge) > < Fuel Injection|Page 1320
Page 1
background image

Radiator Cooling Fan Temperature Sensor / Switch: Testing and Inspection

1.

Connect a suitable ohmmeter onto thermal switch terminals.

2.

Place thermal switch into a container filled with oil. Submerge thermal switch in oil up to its flange. Do not completely submerge thermal switch. 
When an oil bath solution is used to heat the thermal switch, ensure thermal switch does not come in contact with container bottom or its
side or thermal switch damage will result.

3.

Place a suitable thermometer into the oil bath as close to the thermal switch as possible.

4.

Heat the oil bath solution and observe both thermometer and ohmmeter readings.

5.

The thermal switch should activate (as indicated by a small deflection by the ohmmeter needle) with oil bath solution heated to approximately
207-216°F.

6.

Allow thermal switch to cool from approximately 207°F to 198°F. At approximately 198°F, the thermal switch should deactivate (as indicated by a
large deflection on ohmmeter needle).

7.

If the thermal switch does not operate as specified in steps 5 and 6, replace thermal switch assembly.

Temperature Sensor (Gauge) > < Fuel Injection|Page 1320