940 SE L4-2320cc 2.3L SOHC Turbo VIN 87 B230FT (1991)
Control Module HVAC: Description and Operation
Fan Control Module
-
The Power Stage amplifies the control signals to operate the blower motor and control compressor operation.
-
The blower speed is controlled by a power transistor. A relay is connected into the circuit at the highest speed reduce the load on the transistor,
while a second relay controls the operation of the compressor through the low-pressure pressostat on the air receiver/dryer.