Pressure Supply

1st-3rd Gears

Line pressure is supplied at A and the valve moves to the upper position.
The combination of line pressure and spring force prevents the valve from moving downwards when governor pressure B is increased.

Line pressure C applied to the top of the changeover valve holds the valve in the lower position.

4th Gear

Line pressure is now supplied to the middle port D of the signal valve.

Since the governor pressure B is not sufficiently high to move the valve downwards, the valve is held in the upper position by spring force.

The changeover valve remains in the lower position.