C30 T5 L5-2.5L Turbo VIN 67 B5254T7 (2008)
Remove the quick-release connector on the vacuum pump. Install: 999 7108 T-pipe See: Tools and Equipment/999 7108 T-Pipe with the plugged end
on the pump
Connect: 999 5230 PRESSURE METER See: Tools and Equipment/999 5230 Pressure Meter on: 999 7108 T-pipe See: Tools and Equipment/999
7108 T-Pipe.
Install the connector for the pump. Read off the value on: 999 5230 PRESSURE METER See: Tools and Equipment/999 5230 Pressure Meter.
The value must be between 80-90 kPa negative pressure. If not replace the pump. See: Vacuum pump, brake booster. See: Vacuum Pump/Service and
Repair.
Checking the line pressure