 Incorrect crimping as shown above can be caused by: 

-

Stripping the cable too short or too long.

-

Incorrect location in the cable terminal.

-

The cable terminal was incorrectly located in the crimp tool forming section.

Checking the Voltage Drop Over Signal Ground

Measuring the voltage drop over signal ground 

When fault-tracing wiring where a fault is suspected to be due to a ground terminal, check as follows.

Equipment: 
Measurement tool FLUKE 88, 951 0060 MULTIMETER  See: Tools and Equipment/951 0060 Multimeter (or similar).

Warning! Do not measure the voltage drop of a ground terminal for SRS. The cable normally has no voltage. No procedures may be carried out
other than the instructions given.
 