Connector, assembling 

Primary lock 
Check that the cable terminal is undamaged.
Press the cable terminal into the housing.
Check that the seal is correctly positioned and that the cable terminal is properly locked by pulling carefully on the cable.

Secondary lock 
Press the secondary lock into place.

KA Cables, General

KA. Cables, general 

General  
Choice of cable size and rating, cable routing for installing accessories or other installations are not covered here.

-

For  mounting accessories or subsequent wiring work refer to the instructions for the particular part involved.

Normal multiple strand cable 

There are different types of cable. The most common is multiple strand (more than 7 strands) of copper. There are also single strand cables and minimal
strand (2-7 strands).
Cables have different areas and color codes.

Cable area 
Specifications that give a cable area are always based on the area of the core (the copper strands). The cable area does not include the insulation.

Cable insulation (sheath) 
Nearly all cables are of the insulated type and have either single or double insulation.
Some copper cables have no insulation.

Other types of cable 