background image

Odor elimination in evaporator 

-

Insert spray nozzle through power unit/blower fan resistor opening in housing.

-

Cover opening with cloth.

-

Protect interior trim with cloths.

Warning! Use protective goggles and gloves. Ensure that ventilation is good. 

-

Point the nozzle so the agent is sprayed towards the evaporator.

-

Move the nozzle back and forth over the evaporator while spraying, so that. Use all the contents in the bottle.

Operations to complete treatment of evaporator 

Connecting battery 

-

Reconnect battery ground lead.

For C70/V70/S70: 
-

Reinstall power unit according to Replacing the power unit (Electronic climate control) See: Blower Motor/Service and Repair/Removal and
Replacement/Replacing the Power Unit (Electronic Climate Control) in reverse order or blower fan resistor according to Replacing blower fan
rheostat (MCC/STANDARD) See: Blower Motor Resistor/Service and Repair/Removal and Replacement In reverse order.

For the 850: 
-

Reconnect battery ground lead.