Odor elimination in evaporator
-
Insert spray nozzle through power unit/blower fan resistor opening in housing.
-
Cover opening with cloth.
-
Protect interior trim with cloths.
Warning! Use protective goggles and gloves. Ensure that ventilation is good.
-
Point the nozzle so the agent is sprayed towards the evaporator.
-
Move the nozzle back and forth over the evaporator while spraying, so that. Use all the contents in the bottle.
Operations to complete treatment of evaporator
Connecting battery
-
Reconnect battery ground lead.
For C70/V70/S70:
-
Reinstall power unit according to Replacing the power unit (Electronic climate control) See: Blower Motor/Service and Repair/Removal and
Replacement/Replacing the Power Unit (Electronic Climate Control) in reverse order or blower fan resistor according to Replacing blower fan
rheostat (MCC/STANDARD) See: Blower Motor Resistor/Service and Repair/Removal and Replacement In reverse order.
For the 850:
-
Reconnect battery ground lead.