volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Wastegate Actuator|Adjustments|Page 4035 > < Wastegate Actuator|Adjustments|Page 4033
Page 4
background image

Connect: 

-

manometer  999 5646 Pressure gauge  See: Tools and Equipment/999 5646 Pressure Gauge  to the pressure regulator hose

-

pressure regulator  999 5544 REGULATOR  See: Tools and Equipment/999 5544 Regulator  to the manometer.

Note! When taking readings the manometer must always hang vertically from its hook. This is to ensure that the correct values are obtained.
Set the 3-way junction connector handle in its middle position.
 

Screw out the adjustment screw for the pressure regulator completely.
Connect compressed air to the pressure regulator.
Screw in the adjustment screw for the pressure regulator so that the manometer displays the value applicable to the relevant engine. See the table.
3-way junction connector has a vent (drilled hole) where it connects to the pressure regulator. This is to facilitate setting the correct pressure.

Checking and adjusting 

Wastegate Actuator|Adjustments|Page 4035 > < Wastegate Actuator|Adjustments|Page 4033