background image

-

crankshaft 

-

the idler pulley 

-

intake camshaft 

-

exhaust camshaft 

-

water pump 

-

belt tensioner.

Note: 

-

This adjustment is to be made with a cold engine. Suitable temperature is approximately 20°C/67°F. At higher temperatures (with the engine at
operating temperature or a high outside temperature for example) the indicator is further to the right.

-

The illustration shows the position of the indicator at different engine temperatures.

-

Carefully turn the crankshaft clockwise until the timing belt is tensioned. The belt must be tensioned between the intake camshaft pulley, the idler
pulley and the crankshaft

-

Hold the belt tensioner center screw secure. Turn the belt tensioner eccentric counter-clockwise until the tensioner indicator passes the marked
position. Then turn the eccentric back so that the indicator reaches the marked position in the center of the window

-

Hold the eccentric securely. Tighten the center screw. Tighten to 20 Nm.

Check that the indicator is in the correct position.