volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

System Overview|Page 274 > < System Overview|Page 272
Page 3
background image

Measurement range: 0 - 100%
The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Air distribution damper motor position, value (Manual climate control / standard)

Measurement range: 0 - 100%
The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Air distribution selector, defroster position, status (Manual climate control / standard)

The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.
Off = Inactive
On = Active

Air distribution selector, ventilation position, status (Manual climate control / standard)

The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.
Off = Inactive
On = Active

Air distribution selector, floor position, status (Manual climate control / standard)

The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.
Off = Inactive
On = Active

Air distribution selector, floor / defroster position, status (Manual climate control / standard)

The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.
Off = Inactive
On = Active

Temperature damper motor, left activation, value

Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Temperature damper motor, right activation, value

Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Recirculation damper motor activation, value

Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Floor / ventilation damper motor activation, value (Electronic climate control)

Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Defroster damper motor activation, value (Electronic climate control)

Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Air distribution damper motor activation, value (Manual climate control / standard)

Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.

Air quality sensor, value (Electronic climate control)

Measurement range 0 -100%

System Overview|Page 274 > < System Overview|Page 272