background image

module (DMM) recirculation. Off = no increase or reduction in pollutant level.
Level 1 = slow increase in pollutant level.
Level 2 = medium increase in pollutant level.
Level 3 = rapid increase in pollutant level.

Parameters, value

Evaporator temperature

The value indicates the temperature from the evaporator temperature sensor. The value is used by the climate control module (CCM) to regulate
activation of the air conditioning (A/C) compressor.

Measurement range -100 degrees C - 100 degrees C.

With the ignition off and a cold engine, the value must correspond with the ambient temperature.
When the engine is running and the A/C is activated, the climate control module (CCM) will regulate the compressor as follows:

-

Compressor on at 10 degrees C.

-

Compressor off at 6 degrees C.

Passenger compartment temperature sensor (only ECC)

The parameter indicates the value from the passenger compartment temperature sensor. The climate control module (CCM) uses the signal to regulate
the climate in the passenger compartment in the AUTO position.

Measurement range -40 - 90 degrees C.
The value must correspond to the ambient temperature.

Desired position, damper motor, defroster

The value indicates how much the damper for the defroster should be open to correspond to the desired climate control. The climate control module
(CCM) transmits the value to the damper motor module (DMM) defroster via the LIN bus.
Measurement range 0-100%.
100% is full capacity.
0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Actual position, damper motor, defroster

The value indicates how much the damper for the defroster is open. The climate control module (CCM) receives the value from the damper motor
module (DMM) for the defroster via the LIN bus.
Measurement range 0-100%.
0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Desired position, damper motor, recirculation

The value indicates how much the damper for recirculation should be open to correspond to the desired climate control. The climate control module
(CCM) transmits the value to the damper motor module (DMM) recirculation via the LIN bus.
Measurement range 0-100%.
0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Actual position, damper motor, recirculation

The value indicates how much the damper for recirculation is open. The climate control module (CCM) receives the value from the damper motor
module (DMM) recirculation via the LIN bus. Measurement range 0-100%.
0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Desired position, damper motor, temperature left

The value indicates how much the damper for temperature left should be open to correspond to the desired climate control. The climate control module
(CCM) transmits the value to the damper motor module (DMM) temperature left via the LIN bus.
Measurement range 0-100%.
0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Actual position, damper motor, temperature left

The value indicates how much the damper for temperature left is open. The climate control module (CCM) receives the value from the damper motor