volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Control Module HVAC|Testing and Inspection > < System Overview|Page 767
Page 6
background image

module (DMM) temperature left via the LIN bus.
Measurement range 0-100%.
0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Desired position, damper motor, temperature right

The value indicates how much the damper for temperature right should be open to correspond to the desired climate control. The climate control module
(CCM) transmits the value to the damper motor module (DMM) for temperature right via the LIN bus.
Measurement range 0-100%.
0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Actual position, damper motor, temperature right

The value indicates how much the damper for temperature right is open. The climate control module (CCM) receives the value from the damper motor
module (DMM) for temperature right via the LIN bus.
Measurement range 0-100%.
0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Desired position, damper motor, air distribution

The value indicates how much the damper for air distribution should be open to correspond to the desired climate control. The climate control module
(CCM) transmits the value to the damper motor module (DMM) air distribution via the LIN bus.
Measurement range 0-100%.
0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Actual position, damper motor, air distribution

The value indicates how much the damper for air distribution is open. The climate control module (CCM) receives the value from the damper motor
module (DMM) air distribution via the LIN bus.
Measurement range 0-100%.
0% corresponds to a fully closed damper and 100% corresponds to a fully open damper.

Requested blower fan speed

The value indicates how much the blower fan must blow to correspond to the desired climate control. The climate control module (CCM) controls the
blower fan speed by transmitting a signal to the central electronic module (CEM).

Measurement range 0-100%.
0% corresponds to the blower fan switched off, 100% corresponds to maximum blower fan speed.

Power supply

The value indicates the power supply to the climate control module (CCM).

Measurement range 0-50 V.
Normal value approximately 12 V (battery voltage).

Control Module HVAC|Testing and Inspection > < System Overview|Page 767