volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Front Wheel Hub, Measuring Lateral Runout|Page 17177 > < Front Wheel Hub, Measuring Lateral Runout|Page 17175
Page 4
background image

Put the test gauge point against the hub flange as shown in the figure.
Rotate the hub gently.
Note the test gauge runout. Hub maximum lateral run-out:  0.020 mm.
If lateral run-out exceeds the value, replace the hub.

Finishing work 

Remove the test equipment 

Install: 