volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Front Wheel Hub, Measuring Lateral Runout|Page 11315 > < Front Wheel Hub, Measuring Lateral Runout|Page 11313
Page 3
background image

Put the test gauge point against the hub flange as shown in the figure.
Rotate the hub gently. Use a socket to help.
Note the test gauge runout. Hub maximum lateral runout: 0.020 mm.
If lateral run-out exceeds the value, replace the hub.

Finishing work 

Remove the test equipment 

Install: 