volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Pressure Regulator, Checking/Adjusting|Page 6148 > < Wastegate Actuator|Testing and Inspection|Page 6145
Page 1
background image

Wastegate Actuator: Adjustments
Pressure Regulator, Checking/Adjusting

Pressure regulator, checking/adjusting 

Special tools: 
999 5544
999 5646

Manometer
Use test equipment 999 5646 to measure the adjustment pressure. The manometer must always hang vertically when taking readings. This is to ensure
that the values obtained are correct.

Removing the heat deflector plate

Remove the heat deflector plate over the Turbocharger (TC). 4 screws.

Removing the hose for the pressure regulator

Remove the hose for the pressure regulator (marked yellow). Disconnect the hose at the Turbocharger (TC) control valve.
Remove the fresh air intake hose from the Air Cleaner (ACL) to access the hose clamp.

Only S70/V70/C70:

The position and version of the Turbocharger (TC) control valve have been changed on the S70/V70/C70.
Disconnect the hose running backward on the Turbocharger (TC) control valve (marked yellow).

Release the push rod

Remove the split pin from the lever.
Release the push rod. Lift the push rod straight up.

Connecting test equipment

Pressure Regulator, Checking/Adjusting|Page 6148 > < Wastegate Actuator|Testing and Inspection|Page 6145