S60 T5 L5-2.3L Turbo VIN 53 B5234T3 (2002)
Connect:
-
manometer 999 5646 to the pressure regulator hose
-
pressure regulator999 5544 to the manometer.
Note: When taking readings the manometer must always hang vertically from its hook. This is to ensure that the correct values are obtained. Set
the 3-way junction connector handle in its middle position.
Screw out the adjustment screw for the pressure regulator completely.
Connect compressed air to the pressure regulator.
Screw in the adjustment screw for the pressure regulator so that the manometer displays the value applicable to the relevant engine. See the table.
3-way junction connector has a vent (drilled hole) where it connects to the pressure regulator. This is where it facilitates seating the correct
pressure.
Checking and adjusting
Push the lever for the Boost Pressure Control (BPC) valve towards the Turbocharger (TC) housing.
The Boost Pressure Control (BPC) valve must be closed.
Check that the push rod locates on the lever lug.
If necessary, adjust the push rod until it locates.