volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Reading and Clearing Diagnostic Trouble Codes|Page 8383 > < Reading and Clearing Diagnostic Trouble Codes|Page 8381
Page 16
background image

Checking For An Open-Circuit

Check cable between data link connector (DLC) terminal 7 and VGLA control module #B19 for an open-circuit See: Diagnostic Trouble Code Tests and
Associated Procedures/Related Tests and Information/Checking Wiring and Terminals - Permanent Faults 

After performing this procedure See: Checking Communication With Control Module/Verification 
 

Checking Contact Resistance and Oxidation

Checking Contact Resistance And Oxidation

-

Check VGLA control module connector for contact resistance and oxidation, See: Diagnostic Trouble Code Tests and Associated
Procedures/Related Tests and Information/Checking Wiring and Terminals - Permanent Faults 

-

Ignition on.

VCT 2000 connected.
Try to establish communication with the VGLA system by reading out the status for the driver's door door switch.

Has communication with the VGLA system been established?

Yes

-

Test complete

No

-

See: Checking Communication With Control Module/Checking Cables 

Checking Cables

Checking Cables

-

Ignition off.

-

Disconnect VGLA control module. Check fuse 6.

Reading and Clearing Diagnostic Trouble Codes|Page 8383 > < Reading and Clearing Diagnostic Trouble Codes|Page 8381