volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 4474 > < Diagram Information and Instructions|Page 4472
Page 69
background image

Diagrams/Diagnostic Aids/Housings With Round Cavity Opening.

Choose a terminal removal tool with an end that matches the cavity opening.

-

The narrow ended tool is 1.5 mm wide.

-

The wider end is 2.7 mm wide.

Press the cable terminal in the cavity forwards as far as it will go to free the locking tab from the cavity catch.
Insert the terminal removal tool in the groove as illustrated.
Always follow the instructions in Using terminal removal tools See: Diagrams/Diagnostic Aids/Using Terminal Removal Tools which give the correct
working procedure.

-

Proceed to chapter New cable terminal See: Diagrams/Diagnostic Aids/New Cable Terminal Seal sws and plug . Replacing a cable terminal in
order to crimp a new cable terminal.

Housings With Round Cavity Opening

Housings with round cavity opening 

Cable terminals that are extracted without using a terminal removal tool

1.6 Pin/Pin sockets