S80 T6 L6-2.9L Turbo VIN 91 B6294T (2002)
Headlamp Alignment Sensor: Testing and Inspection
Calibrating the position sensor for Bi-Xenon lamps
The position sensor must be calibrated when replacing the rear electronic module (REM) or position sensor for the Bi-Xenon lamps.
Note! The command for calibrating the position sensor also erases all diagnostic trouble codes (DTCs) in the rear electronic module (REM). If
there are diagnostic trouble codes (DTC) stored in the rear electronic module (REM), fault trace accordingly.
-
Someone must sit in the driver's seat during calibration. The person must weigh at least 75 kg. Ensure that the car is unladen and is on a flat
surface
-
Ignition on
-
Click on the VCT2000 symbol
-
Calibrate the position sensor.
Continue - DONE
Numeric Result 0 - Communication fault