S90 L6-2.9L VIN 96 B6304S (1998)
1. Install pump and pipes
-
Put paper over the generator.
There may be oil left in the pump.
-
Install the five mounting screws.
Note that the lower rear mounting screw also holds a connector.
Tighten screws to 25 Nm (18.5 ft. lbs.).
-
Install return hose and pressure hose, use a new O-ring on the pressure hose.
2. Install thermostat housing with radiator hose
3. Install the pump drive belt.
-
Use an interlock-or bar to tension the automatic tensioner.
-
On later versions use socket with a bar.
4. Top up coolant.
5. Top up oil level in the servo reservoir and bleed the system
-
Transmission oil grade:
ATF oil type F. G.
Dexron II D, E, III
Ford Mercon
Volvos synthetic ATF oil, P/N 1 161 317-1.
NOTE:
-
Synthetic oil can be mixed with normal ATF but the cold weather properties are greatly reduced.
-
When changing to synthetic oil the system should be completely emptied of oil.
-
Repeatedly turn the steering wheel to full lock.
Top up oil if necessary.
-
Set the parking brake, then start engine.
-
Check oil level during bleeding.
-
Turn steering wheel slowly to the right, hold on full lock for 10 seconds.