volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

A/C - Unpleasant Odors|Page 19364 > < A/C - Unpleasant Odors
Page 2
background image

Assemble the special tool 999 7065 and 999 7064 and connect the spray gun to the workshop compressed air system. Remove the panel below the
dashboard on the passenger side, see VADIS:

Repair and Installation Function Group 88 Interior equipment Instrument and radio panel Removing the dashboard.

Remove the pollen filter and dry the evaporator

2

Remove the pollen filter cover (A). Pull the pollen filter (B) carefully outwards. If necessary, clean the housing and the evaporator. Install the cover (A).
Open the front windows about 10 cm. Turn the A/C switch to off. Set the heating temperature to maximum. Set the fan to the highest setting. Select
recirculation. Start the engine and let it idle for 15 minutes.

Note! 

Be sure to connect an exhaust hose.

Prepare the vehicle for application of the protective coating

3

After 15 minutes, switch off the engine. Remove the cover (A) of the pollen filter. Turn the ignition switch to position 2. Set the fan switch to position 2.
This ensures complete and thorough coverage when applying the coating. Switch off recirculation. Open the vehicle's doors and ensure that there is
sufficient ventilation. Connect the bottle Part No. 1161570 to the suction line of the special tool.

Note! 