Page 78
background image

The secondary locking must always be adjusted to the initial position.
The secondary locking must be closed in reverse order to the way it was opened.
When the secondary locking is closed a "click" is often heard.
If it cannot be closed it might be because the cable terminal is not completely inserted in the cavity.
If the connector has a sheath, cover or rubber gasket for the housings, do not forget to reinstall it.

After completing the repair work 

-

Replace the battery negative cable terminal on the battery.

-

Check functions for the equipment affected by the repair.

Separate the Connector

Separate the connector

Warning!  SRSNor cable repair or other repair work may be carried out on the SRS wiring. For repairs to the SRS system refer to the
instructions in the SRS Service Manual.

If the connector halves (socket housing and pin housing) are connected together or if the connector is connected to a component, then the connector
halves must first be separated.

General instructions

Note that these are general instructions, variations can occur in practice.
Regard the examples shown and the procedures described as guidelines.

Types of catches and locks

The connector halves are connected to each other by different types of lock tabs/eyes.
 Separation

Note! Never pull the cables when separating. Hold the connector halves.