Connecting the cable to the junction box

7

Route the cable along the existing cable harness under the steering column and onwards to the junction box.
Remove the junction box from the mounting for the dashboard-mounting bracket.
Disconnect the two upper connectors from the central electronic module (CEM) (or remove) to gain better access.
Connect the cable to the junction box at the top right front side. See the illustration.
Secure the cable harness with tie straps. The wiring must not be stretched or positioned where it could come into contact with moving components or
sharp objects.
Reconnect the connectors to the central electronic module (CEM) and reinstall (if removed).
Install the junction box and secure it at the dashboard bracket.

Activating and checking the ventilation system

8

Turn the ignition to position II.

Caution!

Ensure that no one is in the car when connecting the battery.

Connect the battery negative lead. Wait at least 10 seconds.

Caution!

Switch off the ignition after 10 seconds. After approximately 20 seconds, the blower fan motor starts and runs at full speed for approximately two
seconds.

Note!

If the ambient temperature is above 16°C the blower fan motor will start and run two times after another 30 seconds.

Enter the radio code. Set the clock.
Check that the ventilation system is working normally by starting the motor. Check the functions of the ventilation system.

Finishing work

9

Install:
-

the soundproofing panel on the driver's side

-

the two side panels for the center console

-

the soundproofing panel on the passenger side.