volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Procedures|Page 1998 > < Procedures|Page 1996
Page 5
background image

Remove:

-

the screws on the mounting

-

the hose carefully

-

the pipe clip.

Fitting the hose between the compressor and the condenser

Note! Always use new O-rings.

Fit:

-

the pipe clip

-

the hose

-

the O-rings.

Oil the O-rings with AC compressor oil.
Connect the pipe and tighten the bolts by hand.

Tighten:

-

the bolt by the compressor to  22 Nm.

-

the bolt by the condenser to  25 Nm.

Filling coolant

Vacuum pump system as per.
Fill the system with coolant as per  Filling with refrigerant See: Heating and Air Conditioning/Service and Repair/Filling With Refrigerant.
Fill the system with fluorescent dye as per  Filling with fluorescent tracing agent and refrigerant See: Heating and Air Conditioning/Service and
Repair/Filling With Fluorescent Tracing Agent And Refrigerant.
Search for leaks as directed in  Leak tracing, electronic leak tracer See: Heating and Air Conditioning/Testing and Inspection/Component Tests and
General Diagnostics/Leak Tracing, Electronic Leak Tracer  or   Leak tracing, fluorescent tracing agent / UV lamp  See: Heating and Air
Conditioning/Testing and Inspection/Component Tests and General Diagnostics/Leak Tracing Using Fluorescent Tracing Agent And A UV Lamp.

Removal, Replacement and Installation

Pipes and hoses

Warning! Follow the safety rules for work with the heating/ventilation systems, see  Safety instructions when handling refrigerant See: Heating

Procedures|Page 1998 > < Procedures|Page 1996