Place a new O-ring on the sensor

-

Clean housing

-

Route the cable via the protective tube and connect the connector at the bracket

-

Close the protective tube and install the tube in the clamps

-

Place the sensor and tighten the bolt. Tightening torque 10 Nm 

-

Secure cable in the clamp.

Install 
Connector bracket cover.

Start engine. Read any diagnostic trouble codes (DTCs).