Control Assembly: All Technical Service Bulletins
A/C - Air Flow Cycles From Floor To Defrost Vents/Noises

Retailer Technical Journal 21152

Climate System, Fluctuating Airflow

Date 1-22-2010

Reference: VIDA

Note!

If using a printed copy of this Retailer Technical Journal, first check for the latest online version.

AFFECTED VEHICLES

DESCRIPTION: If a customer reports climate system air cycles between the defroster and floor vents and/or noise when changing distribution selection.
The cause is most likely due to the cam-bracket linked to the distribution actuator or the inner defroster flap within the climate unit when it changes
positions.

An improved cam bracket, climate box housing (larger tolerances), and bearings for the defroster flap were introduced in production at the applicable
chassis numbers in header.

SERVICE: Check for diagnostic trouble codes and any exterior mechanical interference and take appropriate action.

Be sure the issue can not be corrected with a software (SW) download and/or a system re-calibration.

If the above mentioned have not correct the issue; remove the Infotainment (Control Module (ICM) and check the date code of the climate unit housing,
the changes went into production "090504" (2009, May 4th).

Checking climate box production date, removal of ICM, see VIDA:

- Removal, replacement and installation

- 3 Electrical system

- 39 Media, communication and navigation

- 393 equipment for entertainment

- Equipment for entertainment

- Information and Entertainment Display