V50 L5-2.4L VIN 39 B5244S7 (2005)
Inflatable curtain (DMIC), destruction
Special tools:
951 2944 Disarm. equipm.for Suppl.Restraint Syst. See: Tools and Equipment/951 2944 Disarm. Equipm.for Suppl.Restraint Syst.
Note! Only applies to C70 (06-)
Preparatory work
Installation of inflatable curtain (DMIC) in mounting fixture
Warning! Use personal protection equipment. See Discarding pyrotechnic components See: Service and Repair/Discarding Pyrotechnic
Components
Install the gas generator with the inflatable curtain in its normal screw joint on the mounting bracket.
Note! Direct the inflatable curtain component away from the user and make sure it extends away from the gas generator.
Screw the mounting bracket to the fixture.
Connecting cables to the inflatable curtain (DMIC)
Remove the key from the discharge box and store so that it is inaccessible for unauthorized use.
Select the correct adapter cable for the gas generator.
Connect the adapter cable to the inflatable curtain. Check that it is properly connected.
Warning! Remove all loose objects on, or directly connected to, the gas generator.
Lay out the connection cable so that the user is nine meters from the inflatable curtain.
Connect the adapter cable to the connection cable and fully extend the leads.
Connect the cable to the discharge box.
Connect the discharge box to a fully charged 12 V battery.