V50 L5-2.4L VIN 39 B5244S7 (2005)
Insert the key and turn it to position 1.
Destroy the gas generator by connecting the rocker switch and push-button.
Turn the key to position 0.
Remove the key from the discharge box and store so that it is inaccessible for unauthorized use.
Warning! Use pliers when removing due to heat development.
If the adapter cable is still attached, detach the adapter cable from the gas generator as soon as possible after destruction. Use protective safety gloves.
Remove the destroyed gas generator from the fixture.
Roll bar (ROPS), destruction
Special tools:
951 2944 Disarm. equipm.for Suppl.Restraint Syst. See: Tools and Equipment/951 2944 Disarm. Equipm.for Suppl.Restraint Syst.
Preparatory work
Installation of roll bar (ROPS) in mounting fixture
Note! Only applies to C70 (06-)
Warning! Use personal protection equipment in accordance with: Discarding pyrotechnic components See: Service and Repair/Discarding
Pyrotechnic Components
Install the roll bar (ROPS) in its normal screw joint on the mounting bracket.
Connecting cables to the roll bar (ROPS)